Skip to main content

Where Can Multi Head Split Systems Be Installed?

Posted in:
Multi-head split system

Multi Head Split System Locations

Multi-head split systems can be installed in any residential or commercial building that has the necessary space, such as houses, duplexes, townhouses, apartments, and offices.

The outdoor condensing unit should be placed in a well-ventilated area, away from direct sunlight and other sources of heat where possible. The indoor units should be installed in the rooms that need cooling. It’s important to make sure that the system is the correct size for the space it’s meant to cool.

Apartment buildings are a common place where we install multi-head split systems, since ducted installations aren’t possible. They require a ceiling void, which most apartments don’t have. A single split system can only cool one room at a time, or you can use internal trunking to position it across from open doorways to get airflow into bedrooms. However, this doesn’t look as nice.

By choosing to install a multi-head split system, it lets you cool multiple rooms at once, with a cleaner look.

Multi Head Split System
Multi Head Split System

Multi Head Split System Installation Examples

2 Head Multi Split System Installation – 2 Bedroom Apartment

When targeting several rooms in an apartment, the best solution is to install a multi-split system. However, there are some limitations to consider such as the interconnecting piping between the indoor and outdoor units, and the positioning of the rooms. To achieve an ideal finish, direct services should be run out through external walls rather than using internal trunking.

Here are some examples of different positioning options, along with their respective benefits and drawbacks. The floor plans demonstrate two choices for the same apartment.

 

Floor Plan of a Multi Head Installation Sydney Apartment
Multi Head Split System Option 1
Multi Head Split Air Conditioner
Multi Head Split System Option 2

We recommend Option 1 as the head unit placement for its attractive finish and no need for internal trunking. However, the head unit in the master bedroom isn’t in the middle of the wall. Despite this, it still works well for heating and cooling the room.

Option 2 moves the master bedroom head unit to the centre of the wall, with internal trunking. This also allows the living room head unit to be repositioned, since its services use the same trunking.

Installation of a head unit in bedroom two may be possible, but the difficulty and expense of running the services might not make it worth the effort. An alternative solution is to install a separate split system to target the second bedroom.

3 Head Multi Split System Installation Bondi – 3 Bedroom Apartment

This multi head split system installation in a Bondi apartment included the following components:

  • 7.1kW Mitsubishi Electric 3 Port Multi Outdoor Unit (MXZ-4F71VGD-A1) positioned on the balcony;
  • 5kW Wall Mounted Indoor Head Unit (MSZ-EF50VGD-A1) for the living room;
  • 2.5kW Wall Mounted Indoor Head Unit (MSZ-EF25VGD-A1) for the master bedroom; and
  • 2.5kW Wall Mounted Indoor Head Unit (MSZ-EF25VGD-A1) for the second bedroom.

This is what the multi-installation looks like on the floor plan:

Floor Plan of a Mitsubishi Electric 3 Head Multi Installation

The layout of the Bondi apartment enabled us to install three multi head units with minimal internal trunking.

In the living room, the head unit was positioned side-to-back with the outdoor unit above the TV. Bedroom two was placed back-to-back with the living room, with both their services sharing the same internal trunking. Lastly, the master bedroom unit was situated in the corner of the room and its services ran outside the building.

This apartment’s floor plan is an example that compliments a multi head split-system installation. Here are photos of the completed multi head split system installation.

Multi-head split system
2.5kW Mitsubishi Electric Multi Head Split System Unit Installed in Bed 2
5kW Mitsubishi Electric Split System Head Unit Installation
5kW Mitsubishi Electric Multi Head Split System Unit Installed in Living
7.1kW Mitsubishi Electric Outdoor Compressor Installation Bondi
7.1kW Mitsubishi Electric Multi Head Outdoor Unit Installed on Apartment Balcony
2.5kW Mitsubishi Electric Multi Head Unit Installation
2.5kW Mitsubishi Electric Multi Head Split System Unit Installed in Master Bedroom

 

4 Head Multi Head Installation in an Apartment

This multi head split system installation in a Dee Why apartment which included the following components:

  • 7.1kW Mitsubishi Electric 4 Port Multi Outdoor Unit (MXZ-4F71VGD-A1) positioned on the balcony;
  • 5kW Wall Mounted Indoor Head Unit (MSZ-AP50VGD-A1) for the lounge room;
  • Three x 2kW Wall Mounted Indoor Head Unit (MSZ-AP20VGD-A1) for the master, second and third bedrooms;

This is what the multi installation looks like on the floor plan:

4 Head Multi Head Installation in an Apartment

 

The challenge of this multi-head split installation was to find a solution for the head units in the lounge and bedroom three, since the owner only wanted to use the master balcony.

To resolve this, we found compromise by placing the lounge head unit above the master bedroom doorway and running services into bedroom two. Unfortunately, this meant that the internal trunking became visible in bedroom two.

To address the second issue in bedroom three, we used a water pump to push the condensation waste water created by the air conditioner outside. This also allowed us to install the internal trunking in the corner of the bedroom two ceiling, making it hardly noticeable.

This complex installation exemplifies the challenges we faced and the compromises necessary to ensure air conditioning reached every room.

5kW Mitsubishi Electric Multi Head Unit Installation Sydney
5kW Mitsubishi Electric Multi Head Unit in Lounge
Multi Head Installers Sydney Using Internal Trunking
Service Concealed in Smart Duct Trunking
2kW Mitsubishi Electric Multi Head Unit Installers Sydney
Lounge Service & Main 2kW Multi Head Unit
2kW Mitsubishi Electric Multi Split System Installers Sydney
2kW Mitsubishi Electric Multi Head Unit in Bed 2
2kW Mitsubishi Electric Multi Split Installation Sydney
2kW Mitsubishi Electric Multi Head Unit in Bed 3

Strata Compliance for Multi Head Split System Installations

Apartment Multi Head Split System Installations

For strata regulations, it is important to know what to do. There are forms to fill out and a detailed explanation of the multi-head AC installation must be provided. The strata committee needs to know what the installation will look like, if it will affect your neighbours, and if it will blend in with the building facade. If there are any questions or requests, we will work with you to make sure they are answered.

We are authorised to install and maintain the world’s leading air conditioning brands:

Ready performs general maintenance and emergency breakdown air conditioning services to Northern Beaches and Sydney customers. Our team of air conditioning technicians are licensed, fully insured and qualified to service the worlds leading brands including Mitsubishi ElectricDaikinFujitsu and Panasonic.

What Our Customers Are Saying

Over 30 years of experience serving customers Sydney wide
Star Rating from Alan Dodson
9 April, 2025
I have given five stars as the process from quote to installation was fast and all options explained to me not only at the quote stage but at all stages of the installation. Clean up after the job was exemplary with no complaints from my better half. So thanks Marcel, Renton, Troy, Danny, Kaye, Greg and Xavier for a job well done. I am not planning on moving house soon but would have no hesitatio…
Star Rating from Noel McClean
8 April, 2025
We couldn’t be happier with the air conditioning installation from Ready Electrical today. Troy, Renzo, Khye, Danny and Xavier were punctual, professional and communicated every step along the way during our installation. The team worked quickly and efficiently, including the final clean up on site. Thanks to the team from Ready Electrical!
Star Rating from Kara Hillier
31 March, 2025
Professional installation and competitive prices. Company excellent to deal with and respond promptly Our installers Renzo & Khye we’re fantastic
Star Rating from Phil McRitchie
31 March, 2025
Polite, thorough and professional service and advice. Highly recommend. Phil
Star Rating from Victor Northhead
27 March, 2025
Ready Electrical & Air Conditioning were excellent. They were professional, punctual, and responded quickly when I had an issue with my aircon. The repair was done efficiently and without any hassle. It’s made a big difference—finally able to sleep properly in this heat. I’d be happy to use their services again.
Star Rating from Liam Geoghegan
27 March, 2025
Punctual and helpful. Will use their services again.
Star Rating from Jacinta Coyne
27 March, 2025
The team at Ready Electrical were great and would definitely recommend to others. I really appreciated the transparent communication and how tidy the place was when they left. So happy with my fans/air con!
Star Rating from Haein Wyzenbeek
21 March, 2025
Troy and Danny were great to have over for our electrical work. Friendly, efficient and tidy. Thanks again guys!
Star Rating from Lou Nash
17 March, 2025
Ready Electrical and Air Conditioning did a wonderful job in my apartment. I would definitely use them again in the future and highly recommend them to anyone needing electrical services.